On Sunday 17 February 2002 05:44 pm, Jaeger, Gerhard wrote:
>I've forgotten to mention, that all the stuff I got from
>Stefan Nilsen (HP 2200), Gene Heskett (EPSON 1250)

Not all of that came from me except as a relay, ISTR I got some 
of that from Reinhard Max.  I played with the calibration 
position,  The starting origins and maximum length and a lamp 
warmup sleep I'd hard coded.

> and
>Allan Hessenflow (UMAX 3400) has been added...
>
>Thanks guys for that...
>  Gerhard

Unforch, its not running the motors now, or has a several minute 
lamp warmup time that I only waited maybe 2 minutes for.  Humm, 
now I recall setting a 180 second warmup in plustek.conf for the 
previous version that didn't work, yup, chopped the last 0 off 
and its goes in the expected time.

Going back to look at the preview, its trashed, totally.  All 
gains are now set for maximum except luminance gamma, and there 
is a faintly reddish image is all I see.  The lamp was on when 
the scan was made. The histogram displays aren't blank, but 
close, only a bit on the left edges of the displays.

Then I tried a 100 dpi scan, with a full page set, a 100 dpi scan 
gets me a black viewer page, with a small bit of red extending up 
from the black ends of the histograms, but not enough to see it 
in the viewer.  I auto-adjust it, and a rescan now shows me a 99% 
black page in the viewer with a small amount of red detail from 
the image, rather like its bleeding through from black.  No real 
change from the preview.

I also have a lamp off in 1 minute set, so I'll wait for that.
It didn't, and it still left the lamp on when xsane was quit.

To recap, the lamp warmup now works, the image isn't, and the 
lamp is left on at quitting time.  A re-run shuts it off.  Is 
that option supposed to be a 1, or a 'yes' ?

I'll see what the diffs are, but thats tommorrow night, its been 
a long weekend of wee hours work at the transmitter & the old 
mans about worn out.

-- 
Cheers, Gene
AMD K6-III@500mhz 320M
Athlon1600XP@1400mhz  512M
98.5+% setiathome rank, not too shabby for a hillbilly

Previous by date: 18 Feb 2002 04:28:59 -0000 Re: Test Version 0.42-0 (Parallelport and USB), Gene Heskett
Next by date: 18 Feb 2002 04:28:59 -0000 Re: Test Version 0.42-0 (Parallelport and USB) - Part 2, Jaeger, Gerhard
Previous in thread: 18 Feb 2002 04:28:59 -0000 Test Version 0.42-0 (Parallelport and USB) - Part 2, Jaeger, Gerhard
Next in thread: 18 Feb 2002 04:28:59 -0000 Re: Test Version 0.42-0 (Parallelport and USB) - Part 2, Jaeger, Gerhard


Powered by ezmlm-browse 0.20.