plustek: insmod pt_drv failed


Previous by date: 23 May 2002 16:41:22 -0000 350 sets Unix Scanner, Kamran Moshari
Next by date: 23 May 2002 16:41:22 -0000 Re: insmod pt_drv failed, Jaeger, Gerhard
Previous in thread: 23 May 2002 16:41:22 -0000 Re: insmod pt_drv failed, Jaeger, Gerhard
Next in thread: 23 May 2002 16:41:22 -0000 Re: insmod pt_drv failed, Jaeger, Gerhard

Subject: Re: insmod pt_drv failed
From: Heiko Schmidt-Evers ####@####.####
Date: 23 May 2002 16:41:22 -0000
Message-Id: <200205232040.27002.Heiko.Schmidt-Evers@gmx.de>

hi.

On Wednesday, 22. Mai 2002 20:29 Jaeger, Gerhard wrote:
> On Monday, 20. May 2002 19:56, Heiko Schmidt-Evers wrote:
> > HI
> >
> > I have the Plustek OpticPro 12000P.
> > When i am trying to load the Plustek Scanner Driver for Linux i get this
> > msg:
> >
> > linux:/home/heiko/scanner/backend/plustek_driver # make load
> > /sbin/modprobe pt_drv || exit 1
> > /lib/modules/2.4.18-4GB/misc/pt_drv.o: init_module: Success
> > Hint: insmod errors can be caused by incorrect module parameters,
> > including invalid IO or IRQ parameters
> > /lib/modules/2.4.18-4GB/misc/pt_drv.o: insmod
> > /lib/modules/2.4.18-4GB/misc/pt_drv.o failed
> > /lib/modules/2.4.18-4GB/misc/pt_drv.o: insmod pt_drv failed
> > make: *** [load] Fehler 1
> > linux:/home/heiko/scanner/backend/plustek_driver #
> >
> Enable the debug output in the kernel module by using
> make clean
> make DEBUG=y all
>
> then reinstall the driver and do the make load step...
> And now do the dmesg step and send us this ouput...

Ok. The dmesg gives me this output:

[...] i deleted the lines, which did not change. 

*********************************************
pt_drv: init_module()
pt_drv : driver version 0.40-18
ProcFsInitialize()
ptdrvInit(0)
Init settings done
ScanData = 0xc2ea4000
Using fast I/O
Requested port at 0x378
parport0: PC-style at 0x378, irq 7 [PCSPP,TRISTATE,EPP]
Requested port (0x378) found
Port mode reported: (0x0047)
Port for device 0 registered
ptdrvOpen(port=0x378)
Try to claim the parport
parport-modi: SPP PS/2 EPP EPP(ECP) PS/2(ECP)
Using EPP-mode
Starting Scanner-Autodetection
************ DETECTP48xx ************
ModelSet4800()
modelInitPageSettings()
A4 set
ModelSet4800() done.
P48xxInitAsic()
DacInitialize()
ImageInitialize()
IOFuncInitialize()
IOInitialize()
MotorInitialize()
Dataport = 0x0378
Ctrlport = 0x037a
Test 0x55
Test 0xAA
Compare data=0x7e and status=0xe, port=0x378
p48xxReadWriteTest()
Found a 96003 ASIC at Reg 0x13
ModelSet4830()
modelInitPageSettings()
A4 set
ModelSet4830() done.
p48xxDoTest()
Bank 0 overwritten
found 0 bytes of memory
No memory ! No scanner...
p48xxReadWriteTest()
Found a 96003 ASIC at Reg 0x13
ModelSet4830()
modelInitPageSettings()
A4 set
ModelSet4830() done.
p48xxDoTest()
Bank 0 overwritten
found 0 bytes of memory
No memory ! No scanner...
p48xxReadWriteTest()
Found a 96003 ASIC at Reg 0x13
ModelSet4830()
modelInitPageSettings()
A4 set
ModelSet4830() done.
p48xxDoTest()
Bank 0 overwritten
found 0 bytes of memory
No memory ! No scanner...
p48xxReadWriteTest()
Found a 96003 ASIC at Reg 0x13
ModelSet4830()
modelInitPageSettings()
A4 set
ModelSet4830() done.
p48xxDoTest()
Bank 0 overwritten
found 0 bytes of memory
No memory ! No scanner...
p48xxReadWriteTest()
Found a 96003 ASIC at Reg 0x13
ModelSet4830()
modelInitPageSettings()
A4 set
ModelSet4830() done.
p48xxDoTest()
Bank 0 overwritten
found 0 bytes of memory
No memory ! No scanner...
detectScannerConnection() returns -9020.
************* ASIC9800x *************
IOInitialize()
ASIC = 0x20
Unknown ASIC-ID
*** DETECTION DONE, result: -9020 ***
ptdrvClose()
MiscRestorePort()
- no need to restore portmode !
Releasing parport
ptdrvShutdown()
cleanup device 0
Port unregistered
ProcFsShutdown()
pt_drv: proc del 'info' root='pt_drv'
pt_drv: proc del 'pt_drv' root='/proc'
pt_drv : no device(s) detected, (-9020)
---------------------------------------------
linux:/home/heiko/scanner/backend/plustek_driver #

What can I do next???

Heiko.



Previous by date: 23 May 2002 16:41:22 -0000 350 sets Unix Scanner, Kamran Moshari
Next by date: 23 May 2002 16:41:22 -0000 Re: insmod pt_drv failed, Jaeger, Gerhard
Previous in thread: 23 May 2002 16:41:22 -0000 Re: insmod pt_drv failed, Jaeger, Gerhard
Next in thread: 23 May 2002 16:41:22 -0000 Re: insmod pt_drv failed, Jaeger, Gerhard


Powered by ezmlm-browse 0.20.